HomeStore

Geotech Variable Frequency Drive for Redi-Flo2

Geotech Variable Frequency Drive for Redi-Flo2

Geotech Variable Frequency Drive for Redi-Flo2 

The Geotech Variable Frequency Drive (VFD) is designed to operate and protect the Redi-Flo2® pump. With the turn of a knob, an operator can precisely control the discharge flow rate from the pump from 8 GPM (30 LPM) to 100 milliliters per minute, to depths down to 280 feet (85m).

15 Foot Extension cord required to connect VFD to Geotech Reel is sold separately.

For use with Geotech Redi-Flo2 Reel Systems

Features:

  • Control flow rate with turn of a knob or push of a button
  • Wide Performance Range
  • IP66/NEMA 4x Enclosure
  • Optimized Volts/Frequency Pattern for efficient operation.
  • Protect your pump from over- & under- voltage, over-current or ground fault

 

Specifications:

Input (115V model) 115V (±10%)/1PH/48-62Hz/23A
Input (230V model)
230V (±10%)/1PH/48-62Hz/23A
Output
1.1kW/400Hz/220V/3PH/5.5A
Wetted Parts: 316 Stainless steel, PTFE, Viton®
Acceleration Time (preset) 0 to 400Hz, 5 seconds
Deceleration Time (preset) 0 to 400Hz, 5 seconds
Recommended Input Protection (115V) Fuse, 600V, 30A, Fast Acting, UL Class CC or J
Recommended Input Protection (230V) Fuse, 600V, 25A, Fast Acting, UL Class CC or J
Power Cord 18AWG, 300V, 6 ft.
Minimum/Maximum Frequency 1Hz/400Hz
Operating Temperature -4-122° F

 

 

 

 

 

 

 

 

 

 

 

 










Resources:

VFD Datasheet

Installation and Operations Manual

Select Options
From $58.10

Original: $165.99

-65%
Geotech Variable Frequency Drive for Redi-Flo2

$165.99

$58.10
Product image 1

Description

Geotech Variable Frequency Drive for Redi-Flo2 

The Geotech Variable Frequency Drive (VFD) is designed to operate and protect the Redi-Flo2® pump. With the turn of a knob, an operator can precisely control the discharge flow rate from the pump from 8 GPM (30 LPM) to 100 milliliters per minute, to depths down to 280 feet (85m).

15 Foot Extension cord required to connect VFD to Geotech Reel is sold separately.

For use with Geotech Redi-Flo2 Reel Systems

Features:

  • Control flow rate with turn of a knob or push of a button
  • Wide Performance Range
  • IP66/NEMA 4x Enclosure
  • Optimized Volts/Frequency Pattern for efficient operation.
  • Protect your pump from over- & under- voltage, over-current or ground fault

 

Specifications:

Input (115V model) 115V (±10%)/1PH/48-62Hz/23A
Input (230V model)
230V (±10%)/1PH/48-62Hz/23A
Output
1.1kW/400Hz/220V/3PH/5.5A
Wetted Parts: 316 Stainless steel, PTFE, Viton®
Acceleration Time (preset) 0 to 400Hz, 5 seconds
Deceleration Time (preset) 0 to 400Hz, 5 seconds
Recommended Input Protection (115V) Fuse, 600V, 30A, Fast Acting, UL Class CC or J
Recommended Input Protection (230V) Fuse, 600V, 25A, Fast Acting, UL Class CC or J
Power Cord 18AWG, 300V, 6 ft.
Minimum/Maximum Frequency 1Hz/400Hz
Operating Temperature -4-122° F

 

 

 

 

 

 

 

 

 

 

 

 










Resources:

VFD Datasheet

Installation and Operations Manual

Geotech Variable Frequency Drive for Redi-Flo2 | PRM Filtration